The right generator for your induction application
Regardless of whether you have a classic heating or demanding high-tech process, the generators in the TruHeat MF Series 3000 / 5000 / 7000 deliver convincing results in any induction application. As a result of their vast power and frequency range, in addition to the variety of available hardware designs and configurations, they are extremely versatile.
5 kHz to 200 kHz, resulting in a broad range of applications.
Available in different structural designs, enabling simple integration in every environment.
Due to variable line voltage (400 V to 480 V).
Well-suited for hardening, soldering, melting, and annealing, as well as for epitaxy and crystal growing.
Flexible adjustment of frequency and inductor current through the parallel oscillating circuit.
Shorter setup times and higher productivity due to flexible parallel oscillating circuit technology.

Diverse applications
The TruHeat MF Series 3000 / 5000 / 7000 generators can be used universally in diverse applications and are used in both classic fields, as well as in high-tech processes. The product family shines in particular when hardening, annealing, soldering, and melting.

Epitaxy
Deposition of single-crystal layers on a substrate of the same material, e.g. in LED manufacturing.

Crystal growing
Artificial manufacturing of crystals, e.g. crucible pulling as per the Czochralski process.
TruHeat MF 3010
Compare product
|
TruHeat MF 3020
Compare product
|
TruHeat MF 3030
Compare product
|
TruHeat MF 3040
Compare product
|
TruHeat MF 5010
Compare product
|
TruHeat MF 5020
Compare product
|
TruHeat MF 5030
Compare product
|
TruHeat MF 7020
Compare product
|
TruHeat MF 7030
Compare product
|
TruHeat MF 7040
Compare product
|
|
---|---|---|---|---|---|---|---|---|---|---|
Output | ||||||||||
Rated output | 10 kW | 20 kW | 30 kW | 40 kW | 10 kW | 20 kW | 30 kW | 20 kW | 30 kW | 40 kW |
Maximum output voltage | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff |
Nominal operating frequency | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz |
Length, power cable | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m |
Network connection data | ||||||||||
Line voltage | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V |
Line frequency | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz |
Network input power | 23 kVA | 25 kVA | 37 kVA | 49 kVA | - | 25 kVA | 37 kVA | 25 kVA | 37 kVA | 49 kVA |
Power factor | 0.96 | 0.96 | 0.96 | 0.96 | 0.96 | 0.96 | 0.96 | 0.96 | 0.96 | 0.96 |
Communication interfaces | ||||||||||
Analog/digital | Yes | Yes |
-
Yes |
Yes | Yes |
-
Yes |
Yes | Yes |
-
Yes |
Yes |
RS 232 / RS 485 | Yes | Yes |
-
Yes |
Yes | Yes | Yes |
-
Yes |
-
- Yes |
Yes |
-
Yes |
PROFIBUS | Yes | Yes |
-
Yes |
Yes | Yes |
-
Yes |
Yes | Yes |
-
Yes |
Yes |
Housing | ||||||||||
Weight | 87 kg | 87 kg | 87 kg | 87 kg | 105 kg | 105 kg | 105 kg | 220 kg | 220 kg | 220 kg |
IP protection class | IP21 | IP21 | IP21 | IP21 | IP21 | IP21 | IP21 | IP54 | IP54 | IP54 |
Cooling requirements | ||||||||||
Max. water pressure | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar |
Min. pressure differential | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar |
Min. flow rate | 16.5 l/min | 16.5 l/min | 16.5 l/min | 16.5 l/min | 16.5 l/min | 16.5 l/min | 16.5 l/min | 21.5 l/min | 21.5 l/min | 21.5 l/min |
Coolant temperature | - 35 °C | - 35 °C | - 35 °C | - 35 °C | - 35 °C | - 35 °C | - 35 °C | - 35 °C | - 35 °C | - 35 °C |
Outer circle | ||||||||||
Weight | 21 kg | 21 kg | 21 kg | 21 kg | 21 kg | 21 kg | 21 kg | 21 kg | 21 kg | 21 kg |
IP protection class | IP54 | IP54 | IP54 | IP54 | IP54 | IP54 | IP54 | IP54 | IP54 | IP54 |
General | ||||||||||
Overall efficiency | 87 % | 87 % | 87 % | 87 % | 87 % | 87 % | 87 % | 87 % | 87 % | 87 % |
Certificates / standards | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity |
Ambient conditions | ||||||||||
Outside temperature | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C |
TruHeat MF 3010
|
TruHeat MF 3020
|
TruHeat MF 3030
|
TruHeat MF 3040
|
TruHeat MF 5010
|
TruHeat MF 5020
|
TruHeat MF 5030
|
TruHeat MF 7020
|
TruHeat MF 7030
|
TruHeat MF 7040
|
|
---|---|---|---|---|---|---|---|---|---|---|
Output | ||||||||||
Rated output | 10 kW | 20 kW | 30 kW | 40 kW | 10 kW | 20 kW | 30 kW | 20 kW | 30 kW | 40 kW |
Maximum output voltage | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff |
Nominal operating frequency | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz |
Length, power cable | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m |
Network connection data | ||||||||||
Line voltage | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V | (±10%) 400 V - 480 V |
Line frequency | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz | 50 Hz - 60 Hz |
Network input power | 23 kVA | 25 kVA | 37 kVA | 49 kVA | - | 25 kVA | 37 kVA | 25 kVA | 37 kVA | 49 kVA |
Power factor | 0.96 | 0.96 | 0.96 | 0.96 | 0.96 | 0.96 | 0.96 | 0.96 | 0.96 | 0.96 |
Communication interfaces | ||||||||||
Analog/digital | Yes | Yes |
-
Yes |
Yes | Yes |
-
Yes |
Yes | Yes |
-
Yes |
Yes |
RS 232 / RS 485 | Yes | Yes |
-
Yes |
Yes | Yes | Yes |
-
Yes |
-
- Yes |
Yes |
-
Yes |
PROFIBUS | Yes | Yes |
-
Yes |
Yes | Yes |
-
Yes |
Yes | Yes |
-
Yes |
Yes |
Housing | ||||||||||
Weight | 87 kg | 87 kg | 87 kg | 87 kg | 105 kg | 105 kg | 105 kg | 220 kg | 220 kg | 220 kg |
IP protection class | IP21 | IP21 | IP21 | IP21 | IP21 | IP21 | IP21 | IP54 | IP54 | IP54 |
Cooling requirements | ||||||||||
Max. water pressure | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar |
Min. pressure differential | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar |
Min. flow rate | 16.5 l/min | 16.5 l/min | 16.5 l/min | 16.5 l/min | 16.5 l/min | 16.5 l/min | 16.5 l/min | 21.5 l/min | 21.5 l/min | 21.5 l/min |
Coolant temperature | - 35 °C | - 35 °C | - 35 °C | - 35 °C | - 35 °C | - 35 °C | - 35 °C | - 35 °C | - 35 °C | - 35 °C |
Outer circle | ||||||||||
Weight | 21 kg | 21 kg | 21 kg | 21 kg | 21 kg | 21 kg | 21 kg | 21 kg | 21 kg | 21 kg |
IP protection class | IP54 | IP54 | IP54 | IP54 | IP54 | IP54 | IP54 | IP54 | IP54 | IP54 |
General | ||||||||||
Overall efficiency | 87 % | 87 % | 87 % | 87 % | 87 % | 87 % | 87 % | 87 % | 87 % | 87 % |
Certificates / standards | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity | CE declaration of conformity |
Ambient conditions | ||||||||||
Outside temperature | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C | 10 °C - 45 °C |
The technical data of all product versions as a download.

Can be used flexibly and worldwide
The amount of space required is low, which means it can be easily integrated in any application environment – the construction with a separate parallel oscillating circuit enables flexible arrangement in the process – a distance of up to 82 feet can be achieved between the generator and the application. With the variable line voltage, the generators can be used globally without technical modifications; the wide variety of available interfaces facilitates configuration and operation.

Ideal solution for temperature-controlled processes
Parallel oscillating circuit technology reduces setup times, improves productivity, and extends the application spectrum. As a result of flexible power control from almost 0% to 100%, temperature-controlled processes can be optimally controlled using the TruHeat MF Series 3000 / 5000 / 7000 generators. Reliability and long-term stability in operation guarantee a high level of productivity and reproducibility of the results. The taps of the MF output transformer enable easy adjustment to various induction processes.
Various options are available to ensure optimal adjustment of the MF generators to the given application.
The output voltage can be switched from 300 V to 600 V, providing optimal adjustment to demanding heating processes.
With the undervoltage trip option, it is possible to switch off the generator via potential-free contacts.
The safety switch device is required for operation of the MF generator or the induction system in the Performance Level according to ISO 13849.

Operating program TruControl Power
Using the Windows-based TruControl Power software, the generator can be conveniently operated, configured, and monitored from a PC or laptop.
The choice of suitable system components means that the MF generators can be optimally adjusted to the required application.

The inductor geometry is specifically adjusted for the required heating process (ring, line or mold inductor).

Coaxial transformers are used for optimal power adjustment between the generator and inductor. They are available with transformation ratios of 6:1, 9:1, and 12:1.

Pyrometers are used for non-contact temperature measurements on surfaces up to 3632 °F. A coupled program controller enables temperature profiles to be followed precisely.

Process coolers ensure reliable dissipation of process heat. Versions are available for various power ranges.
This product range and information may vary depending on the country. Subject to changes to technology, equipment, price, and range of accessories. Please get in touch with your local contact person to find out whether the product is available in your country.